STUDY SUPPORT
From a bicycle light to the magnifying glass: a course on the optics of the eye and of lenses, built as a series of questions. Every section has an interactive figure to use, not just to look at.
The numbers in the figures are orders of magnitude calculated with simplified models, except where a source is cited. They are there to show how the quantities relate to one another, not to make diagnoses.
On r/askscience someone has to choose between two bicycle lights: the cheaper one claims more lumens (lm, total flux), the more expensive one more ‘cd/m²’. They ask which of the two numbers really says how much the light illuminates. To answer, you have to separate four quantities that get mixed up on the packaging, and that is the job of the whole first part of this page.
Try it. How many candelas do you need, at least, in different conditions: speed, dry or wet road, lit or dark street? And which parameter on the box lets you check it: lux at 10 m (StVZO) or beam distance (ANSI FL1)?
Click a drawing to pause it, click again to resume.
Back to the thread to declare the winner. Who wins between light A, 1,000 lumens (lm, total flux) in a 40° beam, and light B, 400 lumens in a 10° beam? Let us put them on a bike at 30 km/h, at night.
And the winner is… nobody. On a dark road B sees the pothole at the stopping distance, but only in a 2.7 m strip: the sides are dark. A covers the whole lane, but only 11 lux (lx = lm/m²) reach that far instead of 30: it does not see the pothole. With the street lights on, A just about makes it. Customise your light to find the best compromise, or tick ‘Best compromise’ and see how little it takes: the right beam matters more than the lumens.
On an AnandTech forum someone has a 1,500-lumen (lm, total flux) projector throwing onto a 110″ screen, in a living room with about ten large windows and white blinds. By day the picture is hard to see. They ask whether a 4,500-lumen model would fix it. To the four quantities above we have to add two more, which do not appear on the packaging but decide what you see.
Back to the thread to declare the winner. This is a lumens (lm, total flux) problem again, but this time for a screen: a 1,500 or a 4,500 lumen projector, on a 110″ screen, in a living room full of windows? How to find your way: on the screen the lumens alone do not count, the contrast does, that is the ratio between the lux (lx = lm/m²) the projector brings and the lux the room brings. A 110″ screen is about 3.3 m²: 1,500 lumens bring about 450 lux onto it, 4,500 lumens about 1,350, and the windows easily add 500. The goal comes from the AVIXA/ANSI image contrast standard: at least 80:1 for a film, 15:1 for slides.
And the winner is… the TV. By day the 1,500 lm projector sits at about 2:1 and the 4,500 lm one at about 4:1, nowhere near 80:1: not even 8,000 lumens are enough, and with an ALR screen it gets to about 26:1. A TV, LED or OLED, is almost black when off and reflects only 1–2% of the light: it holds about 160:1 in full light. Sure enough, the poster moves on to TVs. The projector wins only when the room goes dark: in the dark 1,500 lm give about 700:1, and little more than one lamp on brings it down to about 20:1. Its real advantage is the diagonal: a 120–150″ screen is cheap, a TV that size does not exist or costs a fortune. Tick ‘Fewest lumens for the goal’ and move the room light to see when the projector makes it.
Take-home: what to look at when you buy
Phone
Projector
The nits on the screen are then up to you, through three choices:
Why a more reflective screen does not save the contrast. The screen sends back the projector's light and the room's light with the same reflectance ρ, so ρ cancels out:
contrast ≈ (ρ·Eprojector + ρ·Eroom) / (ρ·Eroom) = 1 + Eprojector / Eroom
What counts is the ratio between the lux (lx = lm/m²) the projector brings and the lux the room brings. You change it with more lumens, a smaller picture or a darker room; with the screen, only if it is ALR, because it sends back the projector's light more than the light from the windows.
The answer lies in a quantity that spec sheets do not list: persistence, that is how long each single image stays lit. The problem starts here: the screen shows still images, one after another, while the eye, when it follows an object, moves continuously. As long as an image stays lit the eye moves on and the image does not: it slides across the retina and leaves a streak. The longer it stays lit, the longer the streak:
blur ≈ speed × persistence
In slow motion. Six screens compared over 50 ms: on the left when the image is lit, in the middle the streak it leaves on the retina, then how you see the moving object and, in the last column, how black that screen gets: at the top you choose how much light there is in the room. Press ‘Slow motion’ and watch the streak grow only while the box is yellow. In the ‘Try it yourself’ box at the bottom, you choose the technology, the hertz, the strobing and the panel (VA or IPS), QLED and Mini-LED included.
LED and OLED keep the image lit for the whole frame: 16.7 ms at 60 Hz, 8.3 ms at 120 Hz. More hertz help, but only if the game really produces that many images per second. A CRT instead lights each phosphor dot for about 1.5 ms and then lets it fade: at 60 Hz it is sharper than an OLED at 120. Plasma sat in between: it bunched its pulses into a few milliseconds, but its phosphor fades more slowly, and it got to about 4 ms. Its frame interpolation, at 60 Hz, changes nothing with a signal already at 60 fps: there is no image to invent. It was there for 24 fps films. That is why old CRTs were unbeatable in motion for decades, and curiously the only things that come close are today's 720 Hz OLED gaming monitors, at 1.4 ms.
The gaming-TV challenge. Take an online shooter, where two things matter: the blur, because the target moves, and the lag between button and screen. Today's TVs offer two recipes for shortening the blur. The first, strategy A: the game at 60 fps (frames per second), HDR (High Dynamic Range) on, and frame interpolation. The TV invents an image between two real ones and reaches 120 Hz (Hz = 1/s), so persistence drops to 8.3 ms. To invent the in-between image, though, it has to wait for the next real one: 16.7 ms of extra lag. The second: the game at 120 fps and BFI (Black Frame Insertion). Half of every refresh is black and persistence drops to 4.2 ms, but the light is halved, and at 60 Hz the screen flickers. Below, strategy A is on the left and the best compromise on the right.
And the winner is… 120 Hz with BFI, if the game runs at 120 fps. It gives 4 px of blur and 9 ms of lag. The light is halved, but in a shooter that does not matter: HDR can be switched off. Interpolation loses instead, because waiting for the real frame brings lag to about 27 ms and leaves halos right on the targets. Real 120 Hz with no tricks passes too, just: 8 px and 5 ms, with all of HDR. If the game only runs at 60 fps, though, no combination passes: with no tricks the blur is 16 px, with BFI at 60 Hz the screen flickers, with BFI at 120 Hz every image is seen double.
In the shooter interpolation loses. And yet, rewatching The Matrix (1999) on a 120 Hz TV with interpolation on, it feels like being there. It is not a contradiction: in a film you get all of the gain and almost none of the price. The Matrix was shot on 35 mm film at 24 fps, like almost all cinema since sound came in.
The gain is huge precisely at 24 fps. In the game interpolation went from 60 to 120 images per second and halved the blur. In a film it goes from 24 to 120: four images in five are invented, persistence drops from 41.7 to 8.3 ms and the blur from 40 to 8 px. The judder in camera pans disappears too, and on OLEDs it shows more because the pixels change instantly.
The price is almost nil. Lag, which was the worst flaw in the shooter, does not matter here: nobody presses buttons, and the TV delays the sound too to keep it with the picture. Halos remain, but you are not aiming at anything, and standard interpolation, which has more time to compute, makes fewer of them than the gaming kind.
And the winner is… interpolation, if you like the soap opera effect. The real world has no frames: the more the motion of the image follows the motion of the eye, the more it looks like reality. Others do not like it, and it is a matter of habit. For almost a century cinema has been 24 fps, while smooth motion belonged to live TV and soap operas, shot on video at 50 or 60 images per second. On top of that, sharp motion reveals what cinema hides: sets, make-up, stunt doubles. It is the same clash there was over The Hobbit (2012), shot at 48 fps. The TV's Filmmaker Mode switches interpolation off to respect the director's 24 fps; the in-between levels remove the judder without going all the way to the soap opera effect.
A curiosity. The bullet time of The Matrix was born with interpolation: the actors were shot with 120 still cameras in a row, and between one shot and the next the compositors inserted interpolated images to make the camera move smooth (Manex, 1999). In those scenes some of the images were invented before the TV even got involved.
The quantities of light are not alternatives to one another: they describe the same light at different points.
Luminance belongs to whatever emits or reflects: the sun, the road. What reaches the eye is not a luminance: it is an illuminance, in lux (lx = lm/m²), and on the retina a retinal illuminance, in trolands (Td = cd/m² × mm²). In the figure each unit has its own colour, the same wherever it appears.
Every source, direct or reflected, always has a luminance and always produces an illuminance on what it strikes. An illuminated matt surface in turn becomes a source:
L ≈ ρ · E / π
where ρ is the reflectance. Light asphalt (ρ ≈ 0.2) under 10,000 lux (lx = lm/m²) has about 600 nits (nit = cd/m²); fresh snow (ρ ≈ 0.85) about four times as much.
For an extended source, the illuminance on the retina depends only on the luminance and the pupil, not on the distance: the solid angle cancels out.
Eretina ∝ L · Apupil / f²
Hence the distinction that matters: glare depends on the illuminance the source produces at the eye, divided roughly by the square of the angle from the line of sight; damage to the retina depends on the luminance of what you stare at and on time.
There are two distinct mechanisms.
For white light there is an ICNIRP rule of thumb: below 10⁴ cd/m² of luminance not even a detailed risk assessment is needed. The real threshold, however, is expressed in radiance weighted on the blue spectrum, not in nits (nit = cd/m²).
The eclipse. The visible part of the sun has the same luminance as the full sun; only the illuminance at the eye falls. The damage is done by luminance, but the alarm bell is rung by illuminance: without discomfort the reflex to look away does not kick in, the pupil dilates, and the retina has no pain receptors. You stare for a long time at a source that burns like the full sun.
The eye drops do not change the lux (lx = lm/m²) at the eye: they change the pupil area, and so the trolands (Td = cd/m² × mm²). Which eye drops constrict the pupil, and which muscle they act on, is drawn in section 3.
The screen. The risk to the retina is negligible, with or without a filter. The real effect is on the body clock: reading for about 4 hours an evening for 5 evenings on a tablet, compared with a paper book, Chang and colleagues measured evening melatonin reduced by 55%, onset of secretion delayed by more than 1.5 hours, falling asleep slower by about 10 minutes and lower alertness in the morning. The effect that matters is the shift of the clock, which with a fixed alarm becomes social jet lag. The conditions of the study (maximum brightness, dimly lit room) have been criticised as exaggerated, and the authors replied; the question is open.
On blue-light filters, the 2023 Cochrane review concludes that they probably do not reduce computer-related eye strain and that the effect on sleep is uncertain, with very low-certainty evidence.
For calculations the eye is treated as a single refracting surface, with a power of about 60 dioptres at rest and an interior of index 4/3: this is the reduced eye. “Reduced” compared with the real eye, which has at least four refracting surfaces (the two faces of the cornea and the two of the lens; six in Gullstrand's schematic eye, which splits the lens into cortex and nucleus). The model reduces them to one: instead of two principal points and two nodal points there is one of each, and the sums take a single formula. That surface is not the real cornea: it lies about 1.6 mm behind it, where the principal planes of the eye fall. Measured from the cornea, the points that matter are:
The N′–retina distance, about 16.7 mm, sets the size of images: one degree of visual field takes up about 0.29 mm of retina, and the sun, when stared at, forms a tiny disc of about 0.15 mm.
The distance that decides everything is the one between the posterior nodal point N′, on the posterior face of the lens, and the focal point F′. It sets the size of the image on the retina and, compared with the fixed N′–retina distance (about 16.7 mm), tells whether the relaxed eye focuses at infinity.
Rule of thumb: about 3 dioptres per millimetre. An eye 1 mm longer is myopic by about −3 D; for the same reason an error of 1 mm in biometry before cataract surgery becomes about 3 D of error in the intraocular lens.
For a near object it is not F′ that must lie on the retina, but the image. The ciliary muscle contracts, the zonule (the suspensory ligaments) slackens, the lens becomes rounder, the power rises and F′ moves forward in front of the retina. The relation is the lens equation, with the distances measured from N′:
1/f = 1/d₀ + 1/dᵢ m = −dᵢ / d₀
Drugs act on the ciliary muscle, which is smooth and controlled by the parasympathetic system through muscarinic receptors. This is why the opposite of pilocarpine is not muscle relaxants, which act on skeletal muscle, but cycloplegics (atropine, cyclopentolate, tropicamide).
The pupil is set by two smooth muscles that pull in opposite directions. The sphincter, a ring around the edge of the pupil, constricts it: it is controlled by the parasympathetic system, along cranial nerve III and the ciliary ganglion, with acetylcholine on M3 muscarinic receptors, the same as the ciliary muscle. The dilator, arranged radially, widens it: it is controlled by the sympathetic system, with three neurons (hypothalamus, ciliospinal centre, superior cervical ganglion) and noradrenaline on α1 receptors. Every eye drop that changes the pupil acts on one of the two. The ciliary muscle, the one for accommodation, lies on the parasympathetic pathway: in fact, it takes almost all the fibres of the ciliary ganglion, about 97%, against 3% for the sphincter. The sympathetic system sends it only a small β2 branch that relaxes it slightly. This is why complete relaxation is obtained by blocking M3 (cycloplegia), not by stimulating the sympathetic system.
The eye drops that only constrict the pupil do not change the optics of the eye: cornea and lens stay the same, with their defects. They change which part of the optics is used. The iris stops the peripheral rays, which are the ones that err the most, so the spot a point leaves on the retina gets smaller. By how much depends on the defect:
The price is light, which follows the area of the pupil, and below about 2 mm diffraction, which spreads light out when it passes through a small hole. It is the same rule as the aperture of a camera. And the eye already knows it: when looking near it constricts the pupil together with accommodation and convergence. The eye drops reproduce only the miosis of the near triad, the only piece the presbyope can still buy.
How small must the spot be? There are two limits. The first is diffraction: even with perfect optics a point becomes a tiny disc, whose core is, at half intensity, about 9/D micrometres wide with the pupil D in millimetres: about 1.3 µm at 7 mm, 3 µm at 3 mm, 6 µm at 1.5 mm. The second is the cones: in the fovea there is one about every 2.5 µm, and a spot smaller than a cone carries no extra detail, because the retina cannot tell it apart. With a pupil of 2.5–3 mm the healthy eye is already close to this limit.
The panels below the rays are at true scale: each small circle is a cone that lights up like a pixel. The angle covered by one cone is its width divided by the focal length N′F′, from the posterior nodal point to the retina: 2.5 µm / 16.7 mm ≈ 0.5 arcminutes.
With the same cones, lengthening N′F′ enlarges the image: the same detail covers more photoreceptors, but the field covered by the fovea narrows, as with a telephoto lens. If the pupil does not grow, the image also gets darker, because the brightness on the retina goes with the inverse square of the f-number, that is the focal length divided by the diameter of the pupil (as in photography: f/2 is bright, f/8 is dark).
With a longer N′F′ the image on the retina would be larger and each cone would cover a smaller angle: more detail. But it would not pay off for us, for four reasons.
Our eye is a generalist's compromise: by day it is already close to the diffraction limit, at dusk it still gets enough light, and it covers a wide field.
Among panoramic photographers the saying is to rotate the camera around the "nodal point". It is a historical inaccuracy: parallax depends only on the centre of perspective, that is the point from which the lines of sight towards the objects start, and that point is the entrance pupil, the image of the aperture stop seen through the front lenses. With a single lens and the stop right against it the two points coincide, and that is where the rule comes from; in a compound lens they separate, by centimetres even in wide-angle lenses.
The posterior nodal point remains important for another reason: together with the focal plane it defines the focal length.
The real eye rotates around its centre of rotation, about 13.5 mm behind the cornea: the "wrong" point for panoramic photography. The entrance pupil is at about 3 mm, N′ at about 7 mm. As the gaze moves, near objects slide a little relative to distant ones: this is ocular parallax, which the brain compensates for.
Three rays are enough: the one parallel to the axis, which after the lens passes through F′; the one through the centre, which is not deviated; the one through F, which comes out parallel. Where they cross is the tip of the image. If after the lens they diverge, you extend them backwards and find a virtual image.
| Lens | Object | Image |
|---|---|---|
| Converging | beyond 2F | real, inverted, reduced, between F′ and 2F′ |
| Converging | at 2F | real, inverted, same size (m = −1) |
| Converging | between F and 2F | real, inverted, magnified, beyond 2F′ |
| Converging | at F | at infinity |
| Converging | inside F | virtual, upright, magnified |
| Diverging | anywhere | virtual, upright, reduced |
The magnifying glass is a converging lens used with the object inside the focal point. It magnifies about 25 cm / f. Reading glasses do the same thing, but are ten times weaker; glasses for myopia are diverging and make things smaller.
An image is real when the light really passes through that point: a sheet of paper placed there catches it, and anyone in the room sees it, because the paper scatters the light in all directions. It is virtual when the rays diverge as if they came from a point they have never passed through: only someone who puts their eye in their path sees it, and it never appears on a sheet of paper.
With a single lens or mirror, inverted means real and upright means virtual. With more elements the rule no longer holds: in the astronomical telescope the final image is inverted but virtual.
Everyday virtual images: the bathroom mirror, the car's side mirror, the door peephole, the bottom of the swimming pool that looks closer. Real images: the projector screen, the camera sensor, the retina, the dot of sunlight concentrated by a lens.
Whether a lens is converging or diverging is decided by where it is thicker, not by the shape of its faces: thicker at the centre it converges, thicker at the edges it diverges. Spectacles are almost always menisci, with both faces curved the same way (from μηνίσκος, little moon).
The meniscus shape is not there to counter spherical aberration, which with a beam as wide as the pupil is negligible. It is there to counter oblique astigmatism: the eye rotates behind the lens, and a lens crossed at a slant behaves as if it had two powers. By curving it around the centre of rotation of the eye, a sideways gaze crosses it almost perpendicularly.
The compound optical microscope lines up two systems of converging lenses. The objective, very close to the slide, has a short focal length: with the slide just beyond its focus it forms inside the tube a real, upside-down, magnified image, the intermediate image. The eyepiece looks at that image like a magnifying glass: if it falls at its focus, parallel rays come out and the eye sees it at infinity, without accommodating.
total magnification = objective magnification × eyepiece magnification
Below the slide is the condenser, also converging: it magnifies nothing, it concentrates the lamp's light on the specimen. Without it the image would stay just as sharp and magnified, only darker: the lenses that make the image are two. Focusing means moving the slide until the intermediate image falls at the eyepiece focus: the coarse knob gets you close, the fine knob finishes the job, because at high magnification a few micrometres are enough to blur the image. And in the first histology lab the letter ‘e’ cut out of a newspaper shows up rotated by 180°: upside down and left to right.
The nosepiece usually carries four objectives. The more they magnify, the smaller the piece of slide you see, the closer they must sit to the slide and the thinner the slice that stays in focus.
| Objective | Total (10× eyepiece) | NA (Numerical Aperture) | Field | Resolution | Working distance | Depth of field |
|---|---|---|---|---|---|---|
| 4× | 40× | 0.10 | 5 mm | 3.4 µm | ≈ 17 mm | ≈ 55 µm |
| 10× | 100× | 0.25 | 2 mm | 1.3 µm | ≈ 10 mm | ≈ 8 µm |
| 40× | 400× | 0.65 | 0.5 mm | 0.5 µm | ≈ 0.6 mm | ≈ 1 µm |
| 100× oil immersion | 1000× | 1.25 | 0.2 mm | 0.3 µm | ≈ 0.15 mm | ≈ 0.6 µm |
Magnification alone does not reveal smaller details: that is decided by the numerical aperture, NA = n · sin θ, where θ is half the angle of the cone of light entering the objective and n the refractive index between slide and lens. In air n = 1, so NA never reaches 1. With a drop of immersion oil, which has the same index as glass (n ≈ 1.515), even the most inclined rays go straight from the slide into the lens instead of bending away or being reflected: that is why the 100× reaches NA 1.25, but only with oil. Dry objectives, instead, are designed for air, and oil makes them worse.
resolution d = 0.61 · λ / NA
There are two focus knobs. The coarse knob moves the stage in large steps and is used with the 4× and the 10×. The fine knob moves it by a few micrometres and is needed with the 40× and the 100×, where the depth of field is about a micrometre. With these objectives the coarse knob is dangerous: the working distance is under a millimetre, and raising the stage crushes the slide against the lens. Luckily the objectives are parfocal: if the image is in focus at 10×, turning the nosepiece to the 40× keeps it almost in focus, and a touch of fine focus is enough. And since the image is upside down, when you move the slide to the right with the stage knobs the image in the eyepiece goes left: at first everyone moves the wrong way.
With visible light, resolution stops at about 0.2 µm: you can see mitochondria, but not the membrane (7–8 nm) nor ribosomes (about 25 nm). From here there are two ways forward. The confocal keeps light, and so almost the same resolution, but throws away the light coming from out of focus: in a thick sample you see a thin, sharp slice, and by stacking the slices you rebuild the cell in 3D. Electron microscopes change the wave: they use electrons, whose wavelength is a hundred thousand times shorter than green light.
λ = h / p ≈ h / √(2 · m · e · V)
Electrons are charged, so the lenses are coils: the magnetic field bends them as glass bends light, and focusing is done by changing the current. The whole column is under vacuum, because air would stop them. Magnetic lenses, though, have strong aberrations, and the real resolution does not reach 3.7 pm: it is about 0.1–0.2 nm, and 1–2 nm on biological sections, because there the limit is the sample.
The TEM (Transmission Electron Microscope) works like a projector: the beam passes through a 50–100 nm section, stained with heavy metals (uranyl, lead) that deflect electrons where they bind, that is on the membranes. It shows the inside, in projection. The SEM (Scanning Electron Microscope) instead does not form an image with lenses: a pencil of electrons scans the surface line by line, and a detector counts the secondary electrons leaving each point. It shows the surface, in relief.
In the SEM the gun stays still: what moves the beam are the scan coils, electromagnets wound around the column. An electron crossing a magnetic field feels the Lorentz force, perpendicular to both its velocity and the field: more current in the coils, stronger field, more deflection. One pair of coils moves the spot horizontally, the other vertically, and their currents rise in a sawtooth, one fast (a line) and one slow (the whole image). It is the same system as the cathode-ray TV in section 0: there the beam drew the image on the phosphor, here it reads it from the sample. The lenses of TEM and SEM are electromagnets too, but instead of moving the beam they squeeze it, as glass does with light.
F = q · v × B
It is the same principle as the first electrocardiograph. In Einthoven's string galvanometer (1901) a silver-coated quartz string, a few micrometres thick, is stretched between the poles of an electromagnet. The heart's current, picked up by the three leads (both hands and one foot dipped in buckets of salt water), runs through it, and the Lorentz force bends it. The string's shadow, magnified by a lens and projected onto moving photographic paper, draws the ECG. There the field is fixed and the current is measured; in the SEM you choose the current, to steer the beam. And with a fixed field and the current in a loop that can rotate, the same push turns the washing machine motor: it is at the bottom of the figure.
| Optical | Confocal | TEM | SEM | |
|---|---|---|---|---|
| Uses | light | laser light, fluorescence | electrons, 60–300 kV | electrons, 1–30 kV |
| Lenses | glass | glass + pinhole | magnetic | magnetic + scanning |
| Resolution | ≈ 0.2 µm | ≈ 0.2 µm, ≈ 0.6 µm in depth | ≈ 0.1–0.2 nm (1–2 nm on tissue) | ≈ 1–10 nm |
| Sample | can be alive | can be alive, labelled | fixed, 50–100 nm section | fixed, dry, metal-coated |
| Shows | colours, 2D | optical sections, 3D | the inside, 2D | the surface, in relief |
All other values (luminances, trolands, irradiances, positions of the cardinal points, parameters of animal eyes) are orders of magnitude from simplified models, the reduced eye first of all.